Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys No No All elevators in the same building shall use the same key for firefighter operation 9/26/2022
A17.1-2016 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 8.6.5.14.3(c) Yes Yes Car safety did not stop the elevator when governor was tripped. Red Tag 5/18/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone does not connect. Phone needs to be reprogrammed 5/18/2023
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.2 Collection of Oil Leakage No No Install cylinder drain line and pit collection container.
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.2 Collection of Oil Leakage Yes No Install cylinder drain line. Drain line shall run to it collection container. 9/26/2022
A17.1-2016 : Elevators 2.36 - Hydraulic Cylinders 8.6.5.5.2 Collection of Oil Leakage No No Install drain line from cylinder head to pit collection container
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 107.1a Yes No Install mechanical means to hold elevator above the pit floor. It shall be non-removable and operated without complete bodily entry. (second notice) 10/1/2024
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 107.1a Yes No Install non-removable means to mechanically hold the elevator above the pit floor to provide safe refuge. The blocking device shall be capable of being operated without complete bodily entry. A17.1 1996 2500.8b 9/25/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) No No No maintenance control plan in machine room
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(a)(1) No No No maintenance records log in machine room
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Over Speed Valve (Red Tag) Yes Yes Overspeed valve does not stop the elevator. Red Tag 5/18/2023
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Yes No Overspeed valve operated correctly but the valve adjustment setting needs to be sealed. 9/25/2023
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 No Yes Perform overspeed valve test 9/26/2022
A17.1-2016 : Elevators 2.31 - Relief Valves 8.6.5.14.1 No Yes Perform pressure relief test 9/26/2022
A17.1-1996 : Elevators 2.14 - Code data plate 215 No No Post code data plate on controller or disconnect
A17.1-1996 : Elevators 2.14 - Code data plate 215 No No Post code data plate on controller or disconnect
A17.1-1996 : Elevators 2.14 - Code data plate 215 No No Post code data plate on controller or disconnect. "ASME A17.1 1996"
A17.1-1996 : Elevators 2.14 - Code data plate 215 No No Post code data plate on controller or disconnect. "ASME A17.1 1996"
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current operating certificate inside machine room
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current state operating certificate inside the machine room
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) No No Post emergency evacuation of passengers form inside machine room
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures No No Post firefighter operating instructions inside the elevator
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures No No Post firefighter operating instructions on car operating panel
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures No No Post firefighter operating instructions on car operating panel
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures No No Post firefighter operating instructions on car operating panel
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) Yes No Replace damaged suspension ropes due to excessive wire breaks. 5/18/2023
A17.1-2016 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 8.6.5.10 Yes No Shorten suspension ropes to maintain proper top runby 10/1/2024
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate not displayed
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate not displayed in machine room
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation No No Test and log firefighter operation monthly
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation No No Test and log firefighter operation monthly