Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x Make door restrictor operational. 10/18/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Existing cab emergency telephone shall work with 24/7 support. 10/24/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency light inoperative. 11/24/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency light does not work. 6/16/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Red Tag) x In cab emergency telephone shall work. 10/18/2018
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) Service fire extinguisher. 11/1/2022
A17.1-1996 : Elevators 3.3 - Top-of-car operating device 1001.2(c)(3) Make car top run station operational. - Reinspection Required 10/25/2018
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.5 Pit light bulbs shall be guarded 11/1/2022
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 Smoke device in pit needs to be remounted on electrical box 11/1/2022
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the state operating certificate shall be displayed in the elevator machine room 11/1/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 10/25/2018
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Fire extinguisher is expired 11/1/2022