Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)13 There is a hole in the hoistway. Hoistways containing passenger elevators shall be fully enclosed and the enclosure shall be of a solid construction to its full height. 8/22/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 Non-elevator related items (mopping supplies) shall not be stored in the machine room. 8/22/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 Non-elevator related wiring shall be enclosed to conform to NFPA70/NEC. Telecomm wiring on back wall shall be enclosed and supported properly. 8/22/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 100.6 Projections, Recesses, & Setbacks in Hoistway Enclosures - Hoistway ledges are greater than 4". They shall be properly beveled. 8/22/2024
MO Minimum : Elevators (A) - Hoistways (A)13 There are multiple holes in the hoistway walls. Hoistways containing passenger elevators shall be fully enclosed and the enclosure shall be of solid construction to its full height. 8/22/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Required documentation & MCP shall be kept in equipment room including wiring diagrams, oil log & fire service log (recorded monthly). 8/22/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate The state operating certificate is expired. 8/22/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 There is a slop sink in the machine room. The machine room is not large enough for sink to be separated from elevator equipment. The slop sink shall be removed and pipes capped. Customer may apply for variance. 8/22/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/24/2024
conversion conversion n/a Machine room shall not be used for storage of non-elevator related items. 1/23/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 1/23/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 9/1/2022
conversion conversion conversion - reinspect x Make emergency phone operational. 7/27/2018