MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Clean oil & debris from pit floor
|
9/22/2022
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not work.
|
6/16/2021
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not ring to 24x7 support.
|
6/18/2021
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not ring to 24x7 support.
|
9/6/2022
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
1001.2(b)(15)
|
x
|
x
|
Failed 125% brake test. Car would not stop at floor level, ran into pit. Red tagged unit.
|
6/18/2021
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide on-site maintenance records.
|
3/15/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Provide on-site maintenance control program.
|
3/15/2024
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
1001.2(c)(2)
|
|
|
Car top outliet has open ground indicated. Repair as needed.
|
9/22/2022
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
1001.2(c)(2)
|
|
|
Car top outlet has open ground indicated. Repair as needed.
|
9/22/2022
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
204.7
|
|
|
Cartop outlet has open ground indicated, repair as needed
|
9/22/2022
|
A17.1-1996 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
202
|
|
|
Top counterweight guide shoe insert is coming out of holder, causing guide to scrape guide rail, repair / replace same
|
9/22/2022
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
Clean pit and oil from floor.
|
9/22/2022
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
Clean pit and oil from floor.
|
9/22/2022
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be on display in the machine room
|
9/22/2022
|