Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency phone not working. Alarm bell ok. 3/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone not working. Bldg phone line. 11/18/2024
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency phone not working. Alarm bell ok. 12/17/2020
MO Minimum : Elevators (I) - Pits (I)5 x Elevator Pit Ladder has not been installed. Unit was Installed in 1950 pit ladders were not required until ASME A17.1, 1955 Code. MO MIN 11 CSR 40-560 Existing Elevators Item (I) Pits I(5) Pit Any pit where the depth is four feet (4') or more shall have a pit ladder installed.
MO Minimum : Elevators (I) - Pits (I)5 no pit ladder pit over 4 ft
MO Minimum : Elevators (I) - Pits (I)5 Pit needs ladder
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x phone in cab not functioning 11/26/2024