Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x The emergency phone is not working.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 perform and post monthly fire service test log in the elevator machine room 1/20/2021
A17.1-2016 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.11.2.1.2(nn) tried to trip the seismic and it would not trip, repair and retest
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 machine room fire extinguisher does not have an inspection tag, have the extinguisher inspected and tagged annually
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.11.2.1.2(j) machine room fire extinguisher is to be inspected and tagged annually 1/20/2021
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h Provide machine room fire extinguisher
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 the junction box and conduit for the pit stop switch, buffer switch, tail sheave switch is rusted in half and wires are exposed in a couple of places, replace rusted out conduit and junction box (2.8.2.1)
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.4.19.13 Broken Suspension Member and Residual Strength Detection Means x Belt monitor for the hoist belts is flashing an error on the new hoist belts that were installed, repair belt monitor 12/19/2024
A17.1-2016 : Elevators 3.23 - Suspension Means 8.11.2.1.3(cc) x The coated steel belt monitor is flashing an error, repair/reset the belt monitor verify that the belts test good 11/14/2022
A17.1-2016 : Elevators 3.23 - Suspension Means 8.11.2.1.3(cc) the hoist belt monitor is showing an error, the belts tested good, replace faulty belt monitor 1/20/2021
A17.1-2016 : Elevators 3.23 - Suspension Means 8.6.3.2 (Re-Inspection) x coated steel belt monitor is flashing an error, test the belts, if good reset the monitor, if bad replace the hoist belts (8.6.3.2.3) 11/8/2023
A17.1-1996 : Elevators 3.26 - Broken rope, chain, or tape switch 209.2c(2) x Coated steel belt monitor is showing errors on several belts, repair belt monitor 11/2/2020
A17.1-2016 : Elevators 3.34 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.6.4.19.17 Earthquake Operation x could not get the seismic to trip, repair and retest (8.6.4.19.17) 11/8/2023
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.1.6(h) Audible/Visual Signal (Re-Inspection) the fire hat light in the car operating panel did not come on during the fire service test 1/20/2021
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate in the machine room expired in 2011, update with current state operating certificate when received
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the copy of the state operating certificate in the machine room is to be updated annually 1/20/2021