A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
An MCP shall be in place as specified in A17.1 2016 - 8.6.1.2.2 and 8.6.1.4
|
1/31/2022
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022)
|
1/31/2022
|
A17.1-1996 : Elevators
|
3.16 - Traveling cables and junction boxes
|
102.1
|
|
|
The traveling cables shall be installed using one of the approved methods required by NFPA 620.41. The cable is improperly hung on the car side.
|
4/5/2024
|
A17.1-1996 : Elevators
|
5.5 - Traveling cables
|
102.2
|
x
|
|
The traveling cable shall be suspended properly on the car side. (Currently hanging from a minerallac strap, should be a kellems grip or spool hanger)
|
12/16/2022
|
A17.1-1996 : Elevators
|
5.5 - Traveling cables
|
102.2
|
x
|
|
The traveling cable shall be suspended properly on the car side. (Currently hanging from a minerallac strap, should be a kellems grip or spool hanger)
|
12/7/2021
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO state operating certificate shall be displayed in the elevator machine room.
|
1/31/2022
|