Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Yes Yes Lift would intermittenly run with landing door in open position.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current state operating certificate shall be displayed in a non-cumbustible frame.
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) Yes No A side panel is missing on the lift. 7/10/2025
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) Yes No Repair pieces of panel hanging off the back of lift. 7/10/2025
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 Yes No Panel is missing above mast, on runway wall, creating a pinch point as car station side of lift travels past this open area before the car reaches the top landing. Opening needs to be covered completely. 10/16/2025
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 Yes No The runway shall be guarded by a solid enclosure extending from the lower landing to a height of at least 42" above upper landing. The sides of the enclosure shall present a smooth surface. 10/16/2025