A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
x
|
The in car emergency telephone shall be operational. - Elevator Red-Tagged for not having a working notification system for emergency situations.
|
4/30/2020
|
A17.1-1996 : Elevators
|
3.16 - Traveling cables and junction boxes
|
1001.2(c)(22)
|
|
|
The traveling cable is damaged under the car and shall be repaired or replaced.
|
7/2/2020
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
x
|
The car alarm bell shall be operational. - Elevator Red-Tagged for not having a working notification system for emergency situations.
|
4/30/2020
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit light shall be operational.
|
7/2/2020
|
A17.1-1996 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
1001.2(e)10
|
x
|
|
The car safeties shall be tested.
|
4/30/2020
|
A17.1-1996 : Elevators
|
3.16 - Traveling cables and junction boxes
|
1001.2(c)(22)
|
|
|
The traveling cable is damaged under the car and shall be repaired or replaced.
|
7/2/2020
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit light shall be operational.
|
7/2/2020
|
A17.1-1996 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
1001.2(e)10
|
x
|
|
The car safeties shall be tested.
|
5/18/2020
|
A17.1-1996 : Elevators
|
3.16 - Traveling cables and junction boxes
|
1001.2(c)(22)
|
|
|
The traveling cable is damaged under the car and shall be repaired or replaced.
|
7/2/2020
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit light shall be operational.
|
7/2/2020
|
A17.1-1996 : Elevators
|
2.7 - Fire Extinguisher
|
1001.2(b)(7)
|
|
|
A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room.
|
4/6/2023
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7a (3)(a) Standby Illumination in the car. (Re-Inspection)
|
x
|
|
The in car emergency lighting shall be operational.
|
4/7/2022
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
4/6/2023
|
A17.1-1996 : Elevators
|
2.13 - Governor,overspeed switch and seal
|
1001.2(b)(28)
|
x
|
|
The governor sheave has excessive wear. Per the manufacturer's specifications, the governor sheave shall be replaced within 30 days.
|
6/29/2022
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
|
|
A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site.
|
4/6/2023
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site.
|
4/6/2023
|
A17.1-1996 : Elevators
|
2.11 - Disconnecting Means and Control
|
210.4
|
|
|
The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device.
|
4/6/2023
|
A17.1-1996 : Elevators
|
2.1 - Access to machine space
|
101.3d
|
|
|
All machine rooms or enclosures shall have a self-locking door and shall be operable from the interior space without the use of a key.
|
4/6/2023
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.6.3.2 (Re-Inspection)
|
x
|
x
|
The suspension means shall be replaced. One belt is damaged/worn. Elevator Red Tagged.
|
6/21/2024
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Due to the condition of the governor sheave, the following category 5 testing items remain: governor pull-out/pull-thru, spinning of governor to calculate electrical and mechanical tripping speeds, car safeties shall be tested with full load at contract speed.
|
6/29/2022
|