Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 1001.2(b)(3) Inspection code Repair or re-lamp light directly above the controller.
A17.1-1996 : Elevators 3.16 - Traveling cables and junction boxes 1001.2(c)(22) The traveling cable is damaged under the car and shall be repaired or replaced.
A17.1-1996 : Elevators 5.6 - Governor-rope tension devices 206.7 2.18.7.2 - Governor tail sheave switch shall be repaired or replaced. (held together by electrical tape)
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be obtained and displayed in the machine room.
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 101.5a Lighting Repair or re-lamp light directly above the controller. (Multi year violation)
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site.
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 MCP fire service testing must be properly documented monthly on log sheet.
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 210.4 Disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device.
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d All machine rooms or enclosures shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean the car top.
A17.1-1996 : Elevators 1.12 - Car enclosure 204 Tighten/repair car interior handrail.
A17.1-1996 : Elevators 3.16 - Traveling cables and junction boxes 1001.2(c)(22) The traveling cable is damaged under the car and shall be repaired or replaced.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Replace the counterweight roller guides where needed for proper operation.
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The counterweight rollers are making a lot of noise. Repair or replace the rollers as needed.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 1001.2(b)(3) Inspection code Make the machine room lighting above the controller operational.
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x In car emergency telephone shall work with 24/7 support. 4/21/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 5/18/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts x 2.26.2.22 - Counterweight buffer gas spring-return switch is broken.
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 1001.2(c)(13) x Replace the counterweight roller guides where needed for proper operation. 5/18/2020
A17.1-1996 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 1001.2(e)10 x The car safeties shall be tested. 5/18/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 12/10/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)12 x Provide testing of Phase 1 & Phase 2 fire service operation. 4/9/2019
A17.1-1996 : Elevators 1.8 - Door closing force 1001.2(a)(8) x Provide and record the door closing force. 4/9/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Provide testing of emergency lights and bell. 4/9/2019
A17.1-1996 : Elevators 2.13 - Governor,overspeed switch and seal 1001.2(b)(28) x Provide category 1 testing of car governor. 4/9/2019