Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. 2/26/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Unit is leaking excessive oil out of plunger packing. Take corrective action as needed.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing A17.1 - 8.6.5.16.5 OSV NOT SEALED. PERFORM RQUIRED 5YR TESTING ON OR BEFORE THE NEXT INSPECTION. 8/1/2021
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) x Elevator is equipped with an overspeed valve that is not sealed. A category 5 test is due on the overspeed valve. 12/8/2023
A17.1-2016 : Elevators 2.39 - Low Oil Protection 8.6.5.12 x Low oil switch is not working. Take corrective action as needed. 12/8/2023
A17.1-1996 : Elevators 2.4 - Machine space 101.1a A 17.2 ITEM 2.4 MACHINE ROOM WALLS OPEN 2'-3' FROM FLOOR ON ALL FOUR WALLS, SHEETROCK REMOVED. 8/1/2021
A17.1-1996 : Elevators 2.4 - Machine space 101.1a MACHINE ROOM WALLS OPEN 2'-3' UP FROM FLOOR, SHEETROCK REMOVED. (WRITTEN UP IN 2018) 8/1/2021
A17.1-1996 : Elevators 3.5 - Normal terminal stopping device 1003.3(k) x UP NORMAL LIMIT WIRED UP IN DOOR INTERLOCK CIRCUIT. ***RE-INSPECTION REQUIRED*** WRITTEN UP IN 2018 2/10/2021
A17.1-1996 : Elevators 3.5 - Normal terminal stopping device 1003.3(k) x A17.1 ITEM 3.5 WIRE - UP NORMAL STOP IN SAFETY CIRCUIT, NOT DOOR INTERLOCK CIRCUIT. 12/9/2019
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x A17.1 - 8.6.5.16.5 OVERSPEED VALVE NOT SEALED, PERFORM REQUIRED 5 YR OSV TESTING WITHIN 90 DAYS PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION. COMMENY SECOND CITING OF UNSEALED OSV. 11/29/2022