Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Provide comb impact test 4/5/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 Provide MCP
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 Provide written maintenance records to be kept on site.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.1 (c) Cracks in handrail,replace
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.2.13 Both handrails have cracks and need to be replaced. Reinspection required.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.2.13 Both handrails have cracks and need to be replaced.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.6.8.1 The right and left side handrails have degraded and shall be replaced.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 8.6.8.4 Combplates Comb plate is missing one tooth. Replace comb plate.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.11.4.2.1 (Re-Inspection) Upper pit light not working 4/5/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.13 Pits need cleaning.