MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
The unsupported raceway in the hoistway (pit) shall be properly installed and supported.
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
The traveling cables shall be installed using an approved method. (Note: the cable was installed without a hanger on the car end and has moved, exposing the wires).
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
|
|
8.6.5.8 - Based on the installation date of 1961, the hydraulic cylinder is assumed to be of the single bottom type. If proof of a safety bulkhead cannot be verified, then the installation shall be altered to meet the requirements of A17.1 2016 - Sections 8.6.5.8, 8.6.3.10, 8.7.3.23.1, and 3.18.3.4
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
The machine room shall be kept clean.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
All machine room wiring shall be enclosed. (Note: The box cover shall be installed where the machine room lights plug in).
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
|