Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
MO Minimum : Elevators (A) - Hoistways (A)16 The unsupported raceway in the hoistway (pit) shall be properly installed and supported.
MO Minimum : Elevators (H) - Machine Rooms (H)8 All machine room wiring shall be enclosed. (Note: The box cover shall be installed where the machine room lights plug in).
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods 8.6.5.8 - Based on the installation date of 1961, the hydraulic cylinder is assumed to be of the single bottom type. If proof of a safety bulkhead cannot be verified, then the installation shall be altered to meet the requirements of A17.1 2016 - Sections 8.6.5.8, 8.6.3.10, 8.7.3.23.1, and 3.18.3.4
MO Minimum : Elevators (H) - Machine Rooms (H)4 The machine room shall be kept clean.
MO Minimum : Elevators (A) - Hoistways (A)16 The traveling cables shall be installed using an approved method. (Note: the cable was installed without a hanger on the car end and has moved, exposing the wires).