Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 8.13 - Handrail systems and safety devices 802.4 No No Replace left side up handrail inlet switch. Switch is broken. Reinspection Required. 11/5/2020
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.5 No No Replace broken step thread. 11/5/2020
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.5 No No Replace broken step tread. 11/5/2020
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 1008.2l Yes Yes Step chains are severely worn. Steps and risers do not mesh. Red tagged out of service. Repair and reinspect. 7/21/2020
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.5 No No Replace broken step thread. 11/5/2020
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.5 No No Broken step tread 8/31/2022
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a No No Clean pits/ drip pans. 8/31/2022
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 1008.2l Yes No Lower end “crab track” excessively noisy. 8/31/2022
A17.1-1996 : Escalators 8.4 - Drive machine and brake 804 Yes Yes Brake torque testing has failed. Repair or replacement of the brake assembly is required. Reinspection is required before the unit can be returned to service. 12/10/2024
A17.1-1996 : Escalators 8.4 - Drive machine and brake 804 Yes Yes Brake test failed, unit removed from service. 12/13/2024
A17.1-2016 : Elevators 7.17 - Step/skirt clearances, panels, and performance index 8.6.8.15.19 No No Failed index test. 8/31/2022
Missouri Minimum : Escalators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Provide index testing, record results. 3/5/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.13 Escalator Cleaning No No Provide unit clean down. 12/2/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Provide index testing, record results. 12/13/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Escalator inspection is not completed. only the bottom machine space and the truss area has been completed. Reinspection is required. 12/10/2024