Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect Yes No Replace the car guide inserts, top & bottom. 8/28/2018
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)6 No No Top guide insert is worn and shall be replaced. 12/13/2018
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 No No Bottom limit switch roller is bad and shall be replaced. Switch does not active. Unit Red-Tagged. 12/13/2018
MO Minimum : Elevators (I) - Pits (I)1 No No The pit shall be kept clean and dry. 12/13/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Emergency light shall work. 12/13/2018
conversion conversion n/a No No Replace the faulty roller on the down slow down switch. 12/13/2018
conversion conversion n/a No No Car emergency lighting does not work. 12/13/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The in car emergency telephone shall be operational. 9/14/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Copper sump pump pipe above pump unit shall be guarded or guttered to protect elevator equipment. 11/8/2022