Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - red tag x x Governor jaws and rope shall be replaced, car safeties would not set. 4/15/2019
conversion conversion conversion - red tag x x Cable on wind up drum is damaged and shall be replaced. 4/15/2019
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 x x Governor jaws and governor rope shall be replaced, car safeties would not set. 5/22/2020
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 x x Cable on wind up drum is damaged and shall be replaced. 5/22/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 6/13/2023
MO Minimum : Elevators (A) - Hoistways (A)13 The holes in the overhead shall be sealed with approved solid material. 6/13/2023
MO Minimum : Elevators (H) - Machine Rooms (H)4 The material not necessary for the operation of the elevator, trash, and defective parts shall be removed from the machine room. 6/13/2023
MO Minimum : Elevators (H) - Machine Rooms (H)8 The covers shall be installed on all electrical equipment in the machine room, including the controllers. 6/13/2023
MO Minimum : Elevators (H) - Machine Rooms (H)6 The machines shall be numbered. 6/13/2023
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log A monthly fire service testing log shall be posted and kept on-site. 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A maintenance control program (MCP) shall be provided. 6/13/2023
MO Minimum : Elevators (H) - Machine Rooms (H)7 Wiring running from controller 1 to controller 2 shall be enclosed in raceway or wireway. 6/13/2023
MO Minimum : Elevators (A) - Hoistways (A)13 Holes in the hoistway between floors 1 and 2 shall be sealed with approved solid materials. 6/13/2023
MO Minimum : Elevators (S) - Fire Service (S)1 x x The door close button shall be operational on firefighters Phase 2 operation. (Doors presently close with car call button, but not with door close button) - The installation year and adopted code at time of installation shall be confirmed to determine if this violation applies. 3/3/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The emergency lighting shall be operational. 3/3/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The alarm bell shall be operational on main and auxiliary power. 3/3/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams An up to date, legible copy of the schematics shall be located in the machine room for each elevator. 6/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers A current ABC type fire extinguisher shall be located in the machine room. 6/13/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Door close button does not work on Phase II fire service. 3/8/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars The car top shall be kept clean. Clean the car top. 6/13/2023
MO Minimum : Elevators (I) - Pits (I)1 The pit shall be kept clean. Clean the pit. 6/13/2023