Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Car door restrictor needs adjustment, make so.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x Door restrictor is out of adjustment, repair as needed. 8/3/2023
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x Adjust restrictor device to prevent opening of doors more than 4" when the car is outside the unlocking zone. Re-inspection required 5/10/2024
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Battery backup lowering unit is not working correctly, repair/replace as needed. 8/3/2023