Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No 2-WAY COMMUNICATION DEVICE SHALL WORK.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be displayed in the elevator machine room. 6/16/2022
A17.1-1996 : Elevators 1.17 - Standby power operation 1002.2g (Standby Power Operation) Yes No Emergency Battery Power/Rescue system shall be tested and operation verified.
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Fire Extinguisher is out of date. 8/12/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Fire service shall be tested. 10/13/2020
A17.1-1996 : Elevators 3.20 - Governor rope 206.5 Governor Ropes Yes Yes Governor rope is frayed and shall be replaced. Unit out of service until replaced and reinspected.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Inspection incomplete due to rated speed being listed at 200 FPM, but the elevator is only running at 125 FPM. The weight portion of the 5-year test shall be completed. 8/25/2026
A17.1-1996 : Elevators 1.3 - Operating control devices 210.1a No No Operating Control Devices: Phone button and phone symbol damaged in COP, currently being held in place by tape.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No The elevator went down during the inspection. The car is stuck on the safeties. Elevator left out of service by elevator maintenance company. 9/18/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Unable to complete inspection due to unit getting stuck on safeties. The following testing items still need to be performed and witnessed to complete the annual inspection. Remaining testing items: Set safeties again, test fire service, testing of governor, testing of car & counterweight buffers, and scan of the hoistway. 9/18/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Unit broke during inspection - The safeties shall be tested as part of a category 5 test. 10/13/2020