Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Toe guard missing from bottom landing hoistway sill. Install toe guard. 11/24/2024
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) Replace the damaged capacity plate and phase 11 fire instructions on the COP 10/20/2020
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone Failed 11/30/2022