A17.1-1996 : Elevators
|
1.17 - Standby power operation
|
1001.2(a)(17)
|
x
|
|
Battery backup system is not working. Repair as needed
|
11/29/2022
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1206.2b (Clean Machine Room)
|
|
|
Remove all non-elevator related materials from the machine room.
|
12/13/2022
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1
|
|
|
Clean the pit of dirt, oil and debris.
|
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1206.2b (Clean Machine Room)
|
|
|
Equipment and materials in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(b)
|
|
|
Update MCP
|
5/1/2022
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5
|
|
|
OSV in pit is not sealed and requires a category 5 weight test to be performed within 90 days or less. Seal upon completion of test
|
5/1/2022
|