Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.17 - Standby power operation 1001.2(a)(17) x Back up battery system is not working. Repair as needed 11/29/2022
A17.1-1996 : Elevators 1.17 - Standby power operation 211.2 x Battery backup is not working. Auxiliary lowering operational shall be functional. 10/25/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(b) Update MCP 5/1/2022
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) Equipment and materials in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Clean the pit of dirt, oil and debris.
A17.1-1996 : Elevators 5.11 Plunger and Cylinder 1206.5b(4) Piston packing are worn and leaking. Repair/replace as needed 5/1/2022
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 OSV in pit is not sealed and requires a category 5 weight test to be performed within 90 days or less. Seal upon completion of test 5/1/2022