Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No The hoistway door at the top landing is missing the access plunger. Replace the missing plunger to allow maintenance and emergency personnel to access the hoistway. 1/15/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No The elevator ADA telephone inside the elevator is not working properly. Check and repair the programming of this phone for proper operation and passenger safety. 4/30/2019
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) Yes No The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required. 2/5/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1002.2f Yes No The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: The fireman’s service phase I key switch bezel is missing and shall be replaced to activate/operate as required. 3/10/2022