Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.17 - Standby power operation 1002.2g (Standby Power Operation) x Emergency battery lowering device is not working. Re-inspection required 2/13/2025
A17.1-2016 : Elevators 4.2 - Hoistway doors 2.11 x First floor landing on front side of elevator has been blocked off on the outside of the hoistway. Door must have all door equipment taken off and hoistway door shall be bolted shut to be taken out of service completely 4/19/2022
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 2.26.12 The car operating panel floor identification numbers are backwards. The front opening buttons are labeled as rear and the rear buttons are labeled as the front landings. 4/19/2022
A17.1-2016 : Elevators 1.3 - Operating control devices 2.26.1 First floor landing on the front side of elevator has been eliminated. The car operating panel must be modified to delete the floor button from the panel 4/19/2022