MO Minimum : Elevators
|
(A) - Hoistways
|
(A)10
|
|
|
Repair or replace access pull boxes with chains.
|
12/8/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.2 Oil Leakage Collection
|
|
|
There is a oil recovery unit installed in the pit of this elevator designed to return the oil leakage from the packing gland on the cylinder head. The State of Missouri has determined that this device does not suffice for oil leakage and is only allowed for temporary use until the packing gland can be repaired/replaced. Remove the recovery unit after the packing gland has been repaired/replaced and record the oil loss per A17.1 2016 - 8.6.5.5.7. Please note that the cylinder diameter of this unit is excessively large and a 5 gallon containment system may not be feasible. Recommend a variance be considered.
|
1/21/2025
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.5.5.2 Oil Leakage Collection
|
|
|
There is a oil recovery unit installed in the pit of this elevator designed to return the oil leakage from the packing gland on the cylinder head to the tank. State of Missouri requires a 5 gallon bucket so the oil leakage can be recorded. Remove Scavenger pump
|
1/21/2025
|
MO Minimum : Elevators
|
(K) - Car Platforms and Car Slings
|
(K)4
|
|
|
The elevator crosshead does not have a data plate. Install a data plate and attach to the crosshead.
|