Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No Replace ceiling panels or guard bulbs inside car. 5/26/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display updated certificate in machine room. 5/26/2020
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 101.5c Receptacles No No Replace bulbs that are out in machine room. 5/26/2020
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Update fire extinguisher in machine room. 5/26/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 No No All lights in the elevator cab shall be protected or be above the drop ceiling. 5/26/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) No No Clean pit. 3/26/2024
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures No No The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: The “call cancel” button is not labeled inside the car and shall be labeled correctly. 8/9/2023
A17.1-1996 : Elevators 1.7 - Car door or gate 204.5 No No Replace missing 24th floor fire tab 6/15/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1002.2f Yes No The fireman’s service phase I key switch has degraded and shall be replaced. The key switch will not allow the phase I key to be removed without great difficulty. 4/10/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1(a)(3) Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Repair emergency alarm, not functioning on battery backup 2/10/2025
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.8 Switch Keys Yes No The fireman’s service phase I key switch has degraded and shall be replaced. The key switch will not allow the phase I key to be removed without great difficulty 2/13/2024
A17.1-1996 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4.10.1.2 - Protection not functioning Yes No The seismic device on the counterweight did not initiate when activated. Repair device to operate when activated. 4/10/2023
A17.1-1996 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4.10.1.2 - Protection not functioning Yes No The seismic device on the counterweight did not initiate when activated. Repair device to operate when activated 4/10/2023
A17.1-1996 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4.10.1.2 - Protection not functioning Yes No Seismic, ring and string, failed to trigger on test. Repair. 11/1/2022
A17.1-2016 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.6.4.19.17 Earthquake Operation No No The seismic device on the counterweight did not initiate when activated. Repair device to operate when activated. 2/13/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Perform the required annual testing of the emergency power generator 2/10/2025
conversion conversion n/a No No Replace hoist cables (Rouge) 10/1/2018
conversion conversion n/a No No Replace ceiling or install guards on cab flourscents. 5/26/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current State Elevator Certificate. 6/15/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No The cab ceiling is of the open type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 8/9/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No A number of lighting fixtures in the elevator cab have been damaged and shall be repaired to at least provide not less than five (5) foot-candles of lighting throughout the cab. 8/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Hoistway door gibs are missing on floors 6 and 22. A hoistway door fire tab is missing on the 2nd floor. Reinstall gibs and fire tab at the locations noted. 8/9/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No The cab ceiling is of the open type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 7/27/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No A number of lighting fixtures in the elevator cab have been damaged and shall be repaired to at least provide not less than five (5) foot-candles of lighting throughout the cab. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Hoistway door gibs are missing on floors 6 and 22. A hoistway door fire tab is missing on the 2nd floor. Reinstall gibs and fire tab at the locations noted. 7/27/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No The hoistway door interlock cover is missing on the 2nd floor, reinstall cover to prevent accidental contact with the electrical interlocks. 8/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Replace missing door Gibs at floors 6 and 11 3/26/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Replace missing fire tab at 2nd floor 3/26/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Replace cover on thw 2nd fllor door lock 3/26/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Hoistway door gibs are missing on floors 6 and 22. A hoistway door fire tab is missing on the 2nd floor. Reinstall gibs and fire tab at the locations noted. 8/23/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No The hoistway door interlock cover is missing on the 2nd floor, reinstall cover to prevent accidental contact with the electrical interlocks. 8/23/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No The fireman’s service phase I key switch has degraded and shall be replaced. The key switch will not allow the phase I key to be removed without great difficulty 4/10/2023