Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Electric Edge on car door is not overridden on Phase I recall. 7/31/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Elevator in car stop switch shall be overridden when Elevator is in Phase 1 after doors close and in return mode to the main egress landing. 7/31/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door needs to be self closing
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) MCP needed
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Per MEMORANDUM 005 A17.1.2016 Section 8.6.5.16.5 Overspeed Valve must be tested/Set and Tagged. Installed in 1998 not tagged.
MO Minimum : Elevators (I) - Pits (I)8 Pit sump hole needs non combustible cover
MO Minimum : Elevators (I) - Pits (I)8 Pit Sump hole shall have a non-combustible cover.
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 x Section 8.6.5.16.5 Overspeed Valves where provided shall be tested & verified. Overspeed valve does not have a test tag must test with Rated Load.
MO Minimum : Elevators (I) - Pits (I)8 Sump pump hole has homemade wooden frame sitting on the top of pit floor over hole.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The single bulb work Light fixture needs replaced with a Dual lamp fixture with lamp guard and have a minimum of 10FC Luxi lite.