A17.1-2016 : Elevators
|
1.3 - Operating control devices
|
8.11.2.1.1(c)
|
|
|
Door close button not working
|
|
A17.1-2016 : Elevators
|
3.3 - Top-of-car operating device
|
2.26.1.4
|
|
|
Car top run station not functioning properly
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
Fire service Phase I operation instructions in main lobby are rubbed off, need to replace signage.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.1 Replacement Parts
|
|
|
Door close button on main car operating panel still not working, needs to be replaced.
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
x
|
Elevator is overdue for Cat 5 testing. Need to perform the following tests to complete the inspection: Full load, full speed safeties, full load, full speed car buffer, full speed counterweight buffer, full load unintended movement, 125% brake lower and hold. Red-tagged until completed. Re-inspection required
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Hoist belts are rouged. Acquire alteration permit and replace belts. Re-inspection required
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone in car is not working. Re-inspection required
|
|
A17.1-2016 : Elevators
|
11.14 - Terminal Stopping Devices
|
2.25.2.2.1
|
x
|
|
Down direction limit does not stop car before going onto final limit switch, repair needed. Re-inspection required
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
x
|
Emergency light & alarm are not working. Red-tagged, re-inspection required.
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Main COP alarm button not working.
|
11/18/2019
|