Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Perform the following tests to complete 5 year inspection: car safeties, car buffer, counterweight buffer, 125% brake, unintended movement 4/6/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Emergency phone in car shall work 4/6/2026
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Light in pit in lowest level needs to work 4/6/2026
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes No Suspension means monitoring device indicates hoist belts need to be replaced. Replace same within 60 days 4/6/2026
A17.1-1996 : Elevators 2.29 - Car and counterweight safeties 1002.2b Yes Yes Safety rod is bent on top of car. Did NOT red tag. Reinspect only. 1/10/2020
A17.1-1996 : Elevators 2.13 - Governor,overspeed switch and seal 1002.2c Yes Yes Gauge bottoms on measurement "D". Replace car governor within 90 days. Did not red tag. 3/13/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Phone not working (line appears to be dead)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No replace missing stop switch button on door operator 4/6/2026