MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency alarm shall work
|
7/22/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Coated steel belt monitor communication was disabled. Communication was re-established, but no maintenance records found of this or any other event in elevator machine room. provide unit maintenance records
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency alarm shall work.
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Fire Service Phase 1 & 2 must be tested, Re-inspection required
|
5/31/2023
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Alarm button on Main COP not working.
|
11/18/2019
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Perform the following tests to complete 5 year inspection: car safeties, car buffer, counterweight buffer, 125% brake, unintended movement
|
7/22/2024
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Perform the following tests to complete 5 year inspection: car safeties, car buffer, counterweight buffer, 125% brake, unintended movement
|
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
2.18.1
|
x
|
x
|
Overspeed governor exceeded maximum allowable pull through measurement. Red tagged. Replace governor and governor rope and retest
|
7/22/2024
|
A17.1-1996 : Elevators
|
2.29 - Car and counterweight safeties
|
1002.2b
|
x
|
x
|
Safety rod bent on top of the elevator. Did NOT red tag. Reinspect only.
|
11/18/2019
|
A17.1-1996 : Elevators
|
2.29 - Car and counterweight safeties
|
1002.2b
|
x
|
x
|
Repair bent safety actuating link rod on car crosshead.
|
1/22/2021
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Coated steel belt monitor communication disabled. Communication re-established but no maintenance records found of this, or any other event, in elevator equipment room. Provide unit maintenance records.
|
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.11.2.1.3(cc)
|
x
|
|
Belt monitor showing bad belts, Unit turned off. Re-inspection required
|
5/31/2023
|
A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
1200.4d
|
x
|
|
Suspension belts showing rouge. Monitor shows replacement. Replace belts in 60 days.
|
11/18/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.23 - Suspension rope
|
8.11.2.1.3(cc)
|
x
|
x
|
The hoist belt monitoring system is disabled with visible rouge present on the hoist belts. The hoist belts shall be replaced with the hoist belt monitoring being re-enabled with an alteration permit being issued and a reinspection performed before the elevator shall be returned to service.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.4 Access to Pit
|
|
|
door to access pit equipment shall be lockable to prevent access by non elevator personnel
|
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.4
|
|
|
door to access pit equipment shall be lockable to prevent access by non elevator personnel
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Repair bent safety actuating link rod on car crosshead. (Governor sheave gauge bottoms on "C" measurement).
|
1/15/2019
|