Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform the following tests to complete 5 year inspection: car safeties, car buffer, counterweight buffer, 125% brake, unintended movement 7/22/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Perform the following tests to complete 5 year inspection: car safeties, car buffer, counterweight buffer, 125% brake, unintended movement
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency alarm shall work.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency alarm shall work 7/22/2024
A17.1-1996 : Elevators 2.29 - Car and counterweight safeties 1002.2b x x Safety rod bent on top of the elevator. Did NOT red tag. Reinspect only. 11/18/2019
A17.1-1996 : Elevators 2.29 - Car and counterweight safeties 1002.2b x x Repair bent safety actuating link rod on car crosshead. 1/22/2021
A17.1-1996 : Elevators 3.23 - Suspension rope 1200.4d x Suspension belts showing rouge. Monitor shows replacement. Replace belts in 60 days. 11/18/2019
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 2.18.1 x x Overspeed governor exceeded maximum allowable pull through measurement. Red tagged. Replace governor and governor rope and retest 7/22/2024
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.4 door to access pit equipment shall be lockable to prevent access by non elevator personnel
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.4 Access to Pit door to access pit equipment shall be lockable to prevent access by non elevator personnel
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Alarm button on Main COP not working. 11/18/2019
A17.1-2016 : Elevators 3.23 - Suspension Means 8.11.2.1.3(cc) x Belt monitor showing bad belts, Unit turned off. Re-inspection required 5/31/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.23 - Suspension rope 8.11.2.1.3(cc) x x The hoist belt monitoring system is disabled with visible rouge present on the hoist belts. The hoist belts shall be replaced with the hoist belt monitoring being re-enabled with an alteration permit being issued and a reinspection performed before the elevator shall be returned to service.
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Fire Service Phase 1 & 2 must be tested, Re-inspection required 5/31/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Coated steel belt monitor communication disabled. Communication re-established but no maintenance records found of this, or any other event, in elevator equipment room. Provide unit maintenance records.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Coated steel belt monitor communication was disabled. Communication was re-established, but no maintenance records found of this or any other event in elevator machine room. provide unit maintenance records
conversion conversion conversion - reinspect x Repair bent safety actuating link rod on car crosshead. (Governor sheave gauge bottoms on "C" measurement). 1/15/2019