Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The sump pump battery back up is not acceptable and battery is giving off fumes. Take corrective action as needed. 8/27/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/27/2021
MO Minimum : Elevators (I) - Pits (I)1 The pit floor shall be kept clean and dry. 8/27/2021
MO Minimum : Elevators (I) - Pits (I)8 The pit sump pump shall have a code compliant cover. 8/27/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light and receptacles are not operational. 10/1/2019
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall be operational. 10/1/2019
conversion conversion conversion - reinspect x In car emergency telephone shall work. 7/27/2018
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/29/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be obtained and displayed in the elevator machine room. 8/27/2021