Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)4 No No Idler sheave on door operator is loose 10/2/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire Extinguisher in Machine Room is due to be serviced or replaced 10/2/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening 5/12/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency Phone in car fails to establish two-way communication 5/12/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes Yes The car door reversal device is bypassed. The doors will continue to operate normally if an object obstructs the infrared beam. The door will hit passengers. 9/30/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Provide signage at each landing instructing occupants that, "In case of Fire, Elevator is out of service" 4/23/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No The Emergency Phone in the car fails to establish two-way communication.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Provide signage at each landing instructing occupants that, "In case of Fire, Elevator is out of service" 10/2/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening 10/2/2025
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine room 10/2/2025
MO Minimum : Elevators (I) - Pits (I)1 No No All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. Oil on the pit floor 10/2/2025
MO Minimum : Elevators (I) - Pits (I)1 No No Remove oil from pit floor 10/2/2025
MO Minimum : Elevators (N) - Guide Rails (N)1 No No Loose guide rail bracket in hoistway 10/2/2025
MO Minimum : Elevators (S) - Fire Service (S)1 Yes No Need Phase II fire service instructions 5/2/2022
MO Minimum : Elevators (S) - Fire Service (S)1 Yes No Stop switch in car is not overridden during Phase I recall 5/2/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No Unsealed overspeed valve due to be tested with rated load. Recurring every 5 years 10/2/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) Yes No Overspeed valves, where provided, shall be inspected and tested to verify that they will stop the car, traveling down with rated load every 5 years. 5/12/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve (Red Tag) Yes Yes Overspeed valves, where provided, shall be inspected and tested to verify that they will stop the car, traveling down with rated load every 5 years. 10/2/2025