Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Elevator cab phone does not work on battery backup, needs repaired. Re-inspection required 10/26/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need a maintenance control program on site posted on controller 12/4/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Door restricter not working 12/28/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Elevator pit lighting does not work, needs repaired. 11/7/2023
A17.1-1996 : Elevators 1.14 - Ventilation 204.3c x Elevator cab ventilation fan does not work on auxiliary power (battery backup), needs repaired. Re-inspection required 10/10/2024
A17.1-1996 : Elevators 1.4 - Sills and car floor 110.11a x Top floor landing plate adjacent to hoistway door landing sill is not fastened properly creating an uneven, loose walking surface (tripping hazard). Secure landing plate. Re-inspection required 10/26/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair inoperative emergency phone. Re-inspection required 10/10/2022
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 x Hydraulic cylinder head packing is excessively light causing erratic operation in up leveling speed, needs repaired. Re-inspection required 10/26/2023
conversion conversion n/a Phone not working on emergency power. Not a reinspection item 12/4/2020
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current operating certificate in machine room. 12/4/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 12/4/2020