Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Fire recall phase one and two shall be tested. Also both buffers and car safeties remain to be tested 7/28/2023
MO Minimum : Elevators (A) - Hoistways (A)1 No No Replace hoistway door sight guards at floor 11. Initially sited on 2/20. 3/31/2026
MO Minimum : Elevators (A) - Hoistways (A)1 No No Replace hoistway door sight guards at floor 11. 3/31/2026
MO Minimum : Elevators (A) - Hoistways (A)1 No No Replace hoistway door sight guards at floor 11. Initially sited on 2/20. 4/3/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency alarm is not working. Re-inspection required 4/4/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency alarm bell does not work on 110v emergency power. Repair or replace 4/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency light and alarm inoperative. 2/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone inoperative on battery back-up power. 2/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No When testing the audible signaling device (alarm bell) with the 110V disconnect in the machine room in the “off” position, the device failed to sound, indicating that either the device is not hooked up to a back-up power device or the back-up power device as failed. Repair for proper operation. Reinspection required. 6/8/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Yes No Hoist ropes are rouged and undersized and shall be replaced (90 days) reinsp
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Clean elevator car top. 3/31/2026
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No Machine room roof is leaking water into machine room. Patch roof leaks to prevent damage to controllers, machines, and car top.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Repair pit light. 3/31/2026
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Repair pit light. 3/31/2026
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) Yes Yes Suspension ropes are well below minimum diameter and rouged. Elevator taken out of service. 5/24/2019
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Provide testing of Phase I operations, record results. 9/13/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Provide testing of Phase II operations, record results. 9/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No The sway guides for the elevator weight compensation chains are worn past their service life and shall be replaced. 4/3/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No This elevator has a backup emergency generator power that is used in case of a power outage. This system shall be scheduled to be tested and a reinspection is required. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Reinspection required. 6/8/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No Emergency Power shall be tested
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) Yes No This elevator has a backup emergency generator power that is used in case of a power outage. This system shall be scheduled to be tested and a reinspection is required. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Reinspection required. 5/21/2025
A17.1-2016 : Elevators 2.17 - Drive machine brake 8.6.4.20.10 Yes Yes Car failed to lower and hold 125%. 9/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean elevator car top. Initially sited on 5/19. 3/31/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean elevator car top. Initially sited on 5/19. 4/3/2026
conversion conversion conversion - reinspect Yes No replace hoist ropes reaching maximum stretch and rouge (30 days). 5/1/2019
conversion conversion conversion - reinspect Yes No emergency phone not working and bell not working on battery power. 5/1/2019
conversion conversion n/a No No Install code data plate. 3/31/2026