A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
|
|
Demarcation lights on both ends are out.
|
|
A17.1-1996 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
Need updated cert displayed in machine room.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.11 - Skirt obstruction device
|
6.1.6.3.6
|
x
|
|
Upper left skirt switch is not working.
|
5/9/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.4 - Drive machine and brake
|
8.6.8.12 Brake
|
x
|
|
Provide testing of brake torque.
|
5/9/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.4 - Drive machine and brake
|
8.6.8.12 Brake
|
x
|
|
Provide brake torque test, record results.
|
8/29/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
6.1.7
|
|
|
Repair switch / electrical box with exposed wiring in lower pit
|
|
conversion
|
conversion
|
n/a
|
|
|
Clean and lubricate skirts to lower index value, left side.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
|
|
Right side handrail stalls about every 2-3 seconds causing the handrail speed sensor to actuate. This could result in stoppage of the escalator. Repair what is causing issue
|
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
A copy of the current state operating certificate shall be displayed in the machine room.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Testing was performed, unit failed. Repair as needed.
|
8/29/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Upper lights are not working.
|
8/29/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Lower lights are not working.
|
8/29/2023
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Post current Certificate.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Provide testing.
|
5/9/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Upper lights not working.
|
5/9/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Lower lights not working.
|
5/9/2023
|
Missouri Minimum : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
Post current State Elevator Certificate.
|
|