Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a No No Demarcation lights on both ends are out.
A17.1-1996 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate No No Need updated cert displayed in machine room.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current State Elevator Certificate.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No Post current Certificate.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No A copy of the current state operating certificate shall be displayed in the machine room.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.11 - Skirt obstruction device 6.1.6.3.6 Yes No Upper left skirt switch is not working. 5/9/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 6.1.7 No No Repair switch / electrical box with exposed wiring in lower pit
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Upper lights are not working. 8/29/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Lower lights are not working. 8/29/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Upper lights not working. 5/9/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Lower lights not working. 5/9/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Right side handrail stalls about every 2-3 seconds causing the handrail speed sensor to actuate. This could result in stoppage of the escalator. Repair what is causing issue
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.4 - Drive machine and brake 8.6.8.12 Brake Yes No Provide brake torque test, record results. 8/29/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.4 - Drive machine and brake 8.6.8.12 Brake Yes No Provide testing of brake torque. 5/9/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index Yes No Testing was performed, unit failed. Repair as needed. 8/29/2023
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index Yes No Provide testing. 5/9/2023
conversion conversion n/a No No Clean and lubricate skirts to lower index value, left side.