Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x Repair top demarcation light. Re-inspection required
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails Both handrails have cracks, need to be replaced.
A17.1-1996 : Escalators 7.3 - Handrails 802.2 Both handrails have cracks. Replace
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.2.13 Right handrail is cracked. Must be replaced.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) x Demarcation strip on step is broken. 4/26/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 6.1.6.3.13 x x Vertical comb step impact device does not actuate until 300 lbs. the maximum allowed is 150 lbs for vertical Impact 5/2/2023
A17.1-1996 : Escalators 7.7 - Combplate and comb step impact device 802.6 Replace lower comb section. broken tooth.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5 x Replace damaged demarcation strips as needed. Re-inspection required
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.6e Step demarcation strips - 3 are broken
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a Demarcation lights on both ends are out.
A17.1-1996 : Escalators 8.4 - Drive machine and brake 804 x x Brake torque failed. Shut unit off. 11/22/2019
conversion conversion n/a Repair malfunctioning upper demarcation lights.
A17.1-1996 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate Display updated operating certificate in machine room.
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate A copy of the current state operating certificate shall be displayed in the machine room