Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.6e No No Step demarcation strips - 3 are broken 12/8/2025
A17.1-1996 : Escalators 7.7 - Combplate and comb step impact device 802.6 No No Replace lower comb section. broken tooth. 12/8/2025
A17.1-1996 : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Certificate No No Display updated operating certificate in machine room. 12/8/2025
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a No No Demarcation lights on both ends are out. 12/8/2025
A17.1-1996 : Escalators 8.4 - Drive machine and brake 804 Yes Yes Brake torque failed. Shut unit off. 11/22/2019
A17.1-1996 : Escalators 7.3 - Handrails 802.2 No No Both handrails have cracks. Replace 12/8/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.7 - Combplate and comb step impact device 6.1.6.3.13 Yes Yes Vertical comb step impact device does not actuate until 300 lbs. the maximum allowed is 150 lbs for vertical Impact 5/2/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.3 - Handrails 8.11.4.2.13 No No Right handrail is cracked. Must be replaced. 12/8/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.9 - Steps and upthrust device 6.1.3.5 Yes No Replace damaged demarcation strips as needed. Re-inspection required 4/28/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.13 - Handrail systems and safety devices 6.1.3.4 No No Left Handrail shall be adjusted to not stall during normal operation
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.5 - Lighting 8.6.11.5(i) Demarcation Lighting (Re-Inspect) Yes No Demarcation strip on step is broken. 4/26/2022
conversion conversion n/a No No Repair malfunctioning upper demarcation lights. 12/8/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting Yes No Repair top demarcation light. Re-inspection required 4/28/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.6.2(i) Step Demarcation No No Need to replace damaged demarcation strips as needed 12/8/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.1 Escalator Handrails No No Both handrails have cracks, need to be replaced. 12/8/2025
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No A copy of the current state operating certificate shall be displayed in the machine room 12/8/2025
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate No No A copy of the current state operating certificate shall be displayed in the machine room