A17.1-2016 : Elevators
|
2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater)
|
8.6.4.19.17 Earthquake Operation
|
x
|
|
Counterweight seismic displacement device does not work, needs repaired. Re-inspection required
|
12/6/2024
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Category 5 full load test was never completed from 12/21/23. Need to perform the following tests to complete CAt 5 full load test: Test drive machine brake with 125% of rated load, perform unintended movement test with 125% of rated load, test car safeties with rated load at rated speed, test car buffer at rated speed with rated load, test counterweight buffer at rated speed. Re-inspection required
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Category 5 full load test is incomplete. Need to perform the following tests: traction machine brake with 125% of rated load. Unintended car movement with 125% of rated load. Car safeties at rated speed with rated load. Car buffer at rated speed with rated load. Counterweight buffer at rated speed with no load. Re-inspection required
|
12/6/2024
|