Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Escalators 7.16 - Ceiling intersection guards 802.3g Replace wrong ceiling intersection guards with correct ones. 7/2/2020
A17.1-1996 : Escalators 7.17 - Step/skirt clearances, panels, and performance index 1206.6c Step indexing over limit. Repair and Reinspect. 3/29/2023
A17.1-1996 : Escalators 7.7 - Combplate and comb step impact device 1206.6 Comb impact guides are rusted. Pressure test on tripping pressure needed. 3/29/2023
A17.1-1996 : Escalators 7.7 - Combplate and comb step impact device 802.6 Replace broken step demarcations. 7/2/2020
A17.1-1996 : Escalators 7.9 - Steps and upthrust device 802.5 Replace broken step demarcation strip. 3/29/2023
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a Clean escalator truss space. 3/29/2023
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a Entire unit needs a clean down. 7/2/2020
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 1206.6 Steps hit comb impact plates in the down direction. Repair 4/14/2021
conversion conversion n/a Install top and bottom inner deck cards. 1/7/2019
conversion conversion conversion - reinspect x comb impact guides are rusted and need to be tested to insure proper impact calibration. 2/21/2019
conversion conversion n/a Replace missing top left end cap weather guard 1/7/2019