A17.1-1996 : Escalators
|
7.5 - Lighting
|
805.7
|
|
|
Upper demarcation light does not work.
|
7/2/2020
|
A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
|
|
Entire unit needs a clean down.
|
7/2/2020
|
A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
|
|
Clean escalator truss space.
|
3/29/2023
|
A17.1-1996 : Escalators
|
7.9 - Steps and upthrust device
|
802.5
|
|
|
Replace broken step demarcation strips.
|
3/29/2023
|
A17.1-1996 : Escalators
|
7.3 - Handrails
|
802.2
|
|
|
Left handrail is stalling.
|
3/29/2023
|
A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
1206.6
|
|
|
Comb impact guides are rusted. Pressure test on tripping pressure needed. Reinspect within 30 days.
|
3/29/2023
|
A17.1-1996 : Escalators
|
8.12 - Steps, step chains, and trusses
|
1206.6
|
|
|
A couple of the steps have broken demarcation strips
|
7/12/2023
|
A17.1-1996 : Escalators
|
7.5 - Lighting
|
805.7
|
|
|
Demarcation light at the top landing does not work
|
7/12/2023
|
A17.1-2016 : Elevators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3.3
|
|
|
Step indexing failed clearances on both side exceeding the allowed .25
|
7/21/2023
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Comb impact guides are rusted and need to be tested to insure proper impact calibration.
|
7/25/2018
|
conversion
|
conversion
|
n/a
|
|
|
Secure impact plate cover to plate.
|
1/7/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace missing top right and left end cap weather guard.
|
1/7/2019
|
conversion
|
conversion
|
n/a
|
|
|
Replace Broken bottom stop switch cover.
|
1/7/2019
|
conversion
|
conversion
|
n/a
|
|
|
Repair inoperative top demarcation light.
|
1/7/2019
|