Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 2.22 x Gas spring-return oil buffers shall be provided with a switch conforming to 2.26.2.22 which shall be actuated if the plunger is not within 13 mm (0.5 in.) of the fully extended position. Currently the switch is not wired. Reinspection required. 4/17/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 2.4.2 x Counterweight runby is 2". Shorten hoist ropes to provide 6-12" runby. Re-inspection required
MO Minimum : Elevators (I) - Pits (I)1 Pit needs to be cleaned