Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current operating certificate shall be on display in the machine room 1/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No High speed down coil on elevator control valve is not being energized, causing elevator to run at leveling speed in the down direction, needs to be repaired 1/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency lights in elevator cab do not work, needs repair. Re-inspection required 10/20/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Elevator cab ceiling is missing, leaving fluorescent light bulbs unprotected. Either re-install cab ceiling or guard bulbs against breakage. 1/27/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A copy of the current state operating certificate shall be displayed in the machine room 1/27/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No High speed down coil on elevator control valve is not being energized, causing elevator to run at leveling speed in the down direction, needs repaired. 1/27/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Elevator cab ceiling is missing leaving fluorescent light bulbs unprotected, Either re-install cab ceiling or guard bulbs against breakage. 1/27/2026
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone shall work. 2/7/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Yes No Bottom left hand cylinder needs to be looked at. 4" of rust on the bottom cylinder. 2/7/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams Yes Yes Water is leaking through drywall ceiling into the elevator controller in machine room causing an unsafe condition. Elevator has been Red-tagged and removed form service. Re-inspection required 10/20/2023