MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing.
|
8/29/2018
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Remove all non-elevator related equipment from the machine room.
|
8/29/2018
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Provide an ABC type fire extinguisher in the machine room.
|
8/29/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Pit shall be kept clean and dry. Remove fluids from the pit.
|
8/29/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Determine the source of fluids in the pit and repair.
|
8/29/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Cab lights shall be guarded to prevent breakage.
|
8/29/2018
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
The existing telephone shall work and call to a number providing 24/7 support.
|
4/9/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove the oil from the pit.
|
6/24/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Replace the leaking cylinder packing.
|
6/24/2019
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Items and materials not related to the function or maintenance of the elevator shall not be stored in the elevator machine room.
|
11/18/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
There is no test tag on the fire extinguisher in the machine room. The fire extinguisher shall be properly tagged to indicate the expiration date and type of extinguisher.
|
11/18/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
7/21/2021
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed in the elevator machine room.
|
7/21/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove oil from the pit. The pit shall be kept clean and dry.
|
7/21/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
|
|
Oil is leaking in the pit. Determine the source of the oil leak and take corrective action.
|
7/21/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Emergency lighting shall be tested and work. No light disconnect in the machine room, nothing labeled as to circuit breaker location.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
Machine room door shall be self-closing and self-locking. Door has been removed. Replace door with appropriate fire rated door.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
|
|
Clean the car top.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
Replace damaged/missing door operator belts.
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)8 Car Lighting
|
|
|
Cab lighting - all lamps shall work.
|
|