Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 8.6.1.4 Need maintenance records onsite. 2/20/2024
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No On-site Maintenance Records 7/20/2023
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d Machine room door not self closing 7/20/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No MCP on site (violation from last year). 7/20/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No on site documentation, no Maintenance log, no call back log, no fire service log. (violation from last year) 7/20/2023
A17.1-1996 : Elevators 2.4 - Machine space 100.3d machine room needs to be self closing (violation from last year). 7/20/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No current operating certificate. (Have not had a current one for 2 years) 7/20/2023
A17.1-1996 : Elevators 1.7 - Car door or gate 204.5 Car Door damaged and does not meet code 204.5g(6). 7/20/2023
A17.1-1996 : Elevators 1.12 - Car enclosure 204 Car enclosure by car door damaged and does not meet code 204.1c 7/20/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No current operating certificate. (Have not had a current one for 2 years) 2/21/2024
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Electrical boxes in machine space needs covers. 2/21/2024
A17.1-1996 : Elevators 4.8 - Hoistway enclosure 100.1 Exhaust vent in hoistway needs a protective assembly (dampener) attached to complete fire rating. 2/21/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.41 - Maintenance Records 8.6.1.4 No on-site documentation accessible for review. 2/2/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone not working Rule 1902.6 1/10/2019
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1206.7 x x Need to have a fire service log on site. Need to correct in 30 days. 4/27/2021
A17.1-1996 : Elevators 1.7 - Car door or gate 204.5 x Car Door damaged and does not meet code 204.5g(6). 2/20/2024
A17.1-1996 : Elevators 1.12 - Car enclosure 204 x Car enclosure by car door damaged and does not meet code 204.1c 2/20/2024
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 x No MCP on site (violation from last year). 2/20/2024
A17.1-1996 : Elevators 2.17 - Drive machine brake 210.8 x The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year) 2/20/2024
A17.1-1996 : Elevators 2.17 - Drive machine brake 1002.3d x The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year) 11/16/2022
A17.1-1996 : Elevators 2.17 - Drive machine brake 1002.3d x The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). 1/27/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone not working (Getting a busy signal). 11/16/2022