MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
8.6.1.4 Need maintenance records onsite.
|
2/20/2024
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
204.5
|
|
|
Car Door damaged and does not meet code 204.5g(6).
|
7/20/2023
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
204.5
|
x
|
|
Car Door damaged and does not meet code 204.5g(6).
|
2/20/2024
|
A17.1-1996 : Elevators
|
1.12 - Car enclosure
|
204
|
x
|
|
Car enclosure by car door damaged and does not meet code 204.1c
|
2/20/2024
|
A17.1-1996 : Elevators
|
1.12 - Car enclosure
|
204
|
|
|
Car enclosure by car door damaged and does not meet code 204.1c
|
7/20/2023
|
A17.1-1996 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
102.1
|
|
|
Electrical boxes in machine space needs covers.
|
2/21/2024
|
A17.1-1996 : Elevators
|
4.8 - Hoistway enclosure
|
100.1
|
|
|
Exhaust vent in hoistway needs a protective assembly (dampener) attached to complete fire rating.
|
2/21/2024
|
A17.1-1996 : Elevators
|
2.1 - Access to machine space
|
101.3d
|
|
|
Machine room door not self closing
|
7/20/2023
|
A17.1-1996 : Elevators
|
2.4 - Machine space
|
100.3d
|
|
|
machine room needs to be self closing (violation from last year).
|
7/20/2023
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1206.7
|
x
|
x
|
Need to have a fire service log on site. Need to correct in 30 days.
|
4/27/2021
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
No current operating certificate. (Have not had a current one for 2 years)
|
7/20/2023
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
No current operating certificate. (Have not had a current one for 2 years)
|
2/21/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
x
|
|
No MCP on site (violation from last year).
|
2/20/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No MCP on site (violation from last year).
|
7/20/2023
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No on site documentation, no Maintenance log, no call back log, no fire service log. (violation from last year)
|
7/20/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No on-site documentation accessible for review.
|
2/2/2024
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No On-site Maintenance Records
|
7/20/2023
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Phone not working (Getting a busy signal).
|
11/16/2022
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Phone not working Rule 1902.6
|
1/10/2019
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
1002.3d
|
x
|
|
The emergency brake cable needs to be repaired (cable not attached to emergency brake handle).
|
1/27/2022
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
1002.3d
|
x
|
|
The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year)
|
11/16/2022
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
210.8
|
x
|
|
The emergency brake cable needs to be repaired (cable not attached to emergency brake handle). (Violation from last year)
|
2/20/2024
|