ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.2.7 | x | Elevators connected to a standby or emergency generator shall be tested for operation on standby or emergency power. Re-inspection required | 1/21/2023 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Need to perform the following tests to complete CAt 5 full load test: Test drive machine brake with 125% of rated load, perform unintended movement test with 125% of rated load, test car safeties with rated load at rated speed, test car buffer at rated speed with rated load, test counterweight buffer at rated speed. Re-inspection required | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not work, possible electrical problem, needs repaired |