Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 8.11.2.1.5(c) 8.6.2.1 The elevator pit and buffer channels are severely corroded and shall be cleaned, repaired, and painted with a rust inhibitor coating. 4/16/2024
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 8.11.2.1.5(c) 8.6.3.1 The elevator pit and buffer channels are severely corroded and shall be cleaned, repaired, and painted with a rust inhibitor coating. 4/16/2024
MO Minimum : Elevators (H) - Machine Rooms (H)4 Everything not related to the elevator shall be removed from the machine room. 10/10/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The ADA telephone inside the elevator is not working properly. Check and repair the phone line for proper operation and passenger safety. This will require a reinpection to verify compliance. (Correct Code: 8.10.2.2.1(f)) 11/6/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 8.6.4.5 x x The elevator car safety assembly on the counterweight side failed to reset properly after performing the 5 year annual test. The safeties shall be repaired or replaced and reinspection performed. 2/22/2024