MO Minimum : Elevators
|
(A) - Hoistways
|
(A)1
|
|
|
Hoistway doors have 2 escutcheon holes. Fill unused hole.
|
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
COP shall be securely attached to cab interior. Currently leaning against wall.
|
2/13/2026
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
2-WAY Communication device shall work and be Code Compliant.
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
Detector edge shall work (not currently installed).
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
x
|
|
Car Door Restrictor shall work entire length of hoistway, when outside of door zones. (not currently installed)
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Remove unused/not required Heat detectors in Machine Room and Top of Hoistway orthey shall work properly. (no Sprinklers or Shunt).
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Top Emergence Exit shall be hinged or otherwise attached to the cartop(chain, etc) and properly secured (wingnut, etc) (currently not attached or bolted.)
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Top emergency exit electrical contact shall work. (Switch not installed, Required as of 2000.)
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Roof Access door has disconnected/broken “hold open” latch. Safety hazard.
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Clearance between car door panel and the car entrance jamb exceeds 13mm(0.5in) (COP jamb)
|
2/13/2026
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
Machine Room shall have proper Fire Extinguisher and shall have current monthly/annual test tag. (Expired2016).
|
2/13/2026
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Machine room door shall be self-closing and self-locking.
|
2/13/2026
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
Machine room lighting needs to be repaired, 1 or more bulbs not working.
|
2/13/2026
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
This inspection was to allow temporary usage of the elevator. The temporary use inspection was stopped as the elevator would not pick the rated load. The 5 year testing required for the temporary usage inspection shall be completed.
|
6/13/2023
|